Alloy Gate Valve

Alloy Gate Valve

1、You are in restricted area and need password. Please Contact us to obtain documents.

2、PasswordIf you have any questions about quotation or cooperation, please feel free to send us inquiry. Inquiry us

Brochure:
Manual: Download
3D step: Download
Certificates: Download
Quote
1.Specification
Size: 2"-68"
Pressure: 150LB-2500LB
Body Material: WC6, WC9, CF8, CF8M, CF3, CF3M, CN7M, LC1, LC2, LC3, LCB, LCC, Monel, 20# Alloys, 4A, 5A, etc.
Seal Material: STELLITE, 13Cr, SS304, SS316, etc.
Connection Type: Flanged, Butt Welded, Socket Welded, NPT
Operation: Handwheel, gear operated, pneumatic, motorized
Face to Face Dimension: ASME B16.10
Flange End Dimension: ASME B16.5
Butt Welded Dimension: ASME B16.25
Design and Manufacture: API 600
Test Standard: API 598, API624, API 6FA, ISO 15848-1-2
2.Features

Through conduit gate valve without diversion holes

Valve equipped with position indication to indicate valve opening and closing

Flat gate valve seat with O-ring seal and preload applied floating seat structure

Non-diversion hole type and diversion hole type are both available

3.FAQ
How to Change a Gate Valve?

Changing a gate valve typically involves the

Shut off the water supply: Before attempting to change a gate valve, you must first turn off the water supply to the valve. This can be done by locating the main water supply valve and turning it off. api 6d ball valve

Drain the water: After turning off the water supply, you must drain the water from the pipes connected to the valve. You can do this by opening a faucet located below the valve.

Remove the old valve: Once the water is drained, you can proceed to remove the old valve. Start by removing any screws or bolts that are holding the valve in place. You may also need to use a wrench to loosen any nuts or fittings that are holding the valve in place.

Install the new valve: Once the old valve is removed, you can install the new valve. This involves connecting the new valve to the pipes and tightening any nuts or fittings. Make sure to use thread sealant or plumber's tape to ensure a tight seal.

Turn on the water supply: After the new valve is installed, you can turn the water supply back on and test the new valve to make sure it is working properly. Check for any leaks or other issues before closing up the area around the valve. forged ball valve

It's important to note that gate valves can vary in size and configuration, so it's always a good idea to consult the manufacturer's instructions or seek the assistance of a professional plumber if you are unsure about how to change a gate valve.

How to Disassemble a Gate Valve?

Disassembling a gate valve can be a complicated process, and it's important to approach it carefully to avoid damaging the valve or causing injury. Here are the general steps to disassemble a gate valve:

Shut off the water supply: Before attempting to disassemble a gate valve, you must first turn off the water supply to the valve. This can be done by locating the main water supply valve and turning it off.

Remove the handle: Once the water supply is shut off, you can remove the handle from the valve. This may involve unscrewing a retaining nut or using a wrench to loosen a set screw.

Remove the bonnet: The bonnet is the housing that covers the stem of the valve. To remove the bonnet, you may need to use a wrench to loosen any nuts or fittings that are holding it in place. Be careful not to damage the threads on the bonnet or the valve body.

Remove the stem: With the bonnet removed, you can now remove the stem from the valve body. This may involve unscrewing a packing nut or using a wrench to loosen a set screw.

Remove the gate: Once the stem is removed, you can now remove the gate from the valve body. This may involve unscrewing a gate retainer or using a wrench to loosen a set screw.

It's important to note that gate valves can vary in size and configuration, so it's always a good idea to consult the manufacturer's instructions or seek the assistance of a professional plumber if you are unsure about how to disassemble a gate valve. Additionally, be sure to wear appropriate safety gear, such as gloves and eye protection, when working with gate valves. carbon steel gate valves

How to Free a Seized Gate Valve?

A gate valve that is seized or stuck can be a frustrating problem, but there are a few things you can try to free it up. Here are some general steps to free a seized gate valve:

Apply penetrating oil: A good first step is to apply a penetrating oil to the valve. This can help to break up any rust or debris that may be causing the valve to stick. Be sure to use a penetrating oil specifically designed for plumbing applications. high temperature gate valves

Tap the valve: If the penetrating oil doesn't work, you can try tapping the valve gently with a hammer or mallet. This can help to loosen any debris or corrosion that may be causing the valve to stick.

Apply heat: In some cases, applying heat to the valve can help to free it up. You can use a propane torch or heat gun to apply heat to the valve body, being careful not to damage any nearby components.

Use a pipe wrench: If none of the above methods work, you can try using a pipe wrench to turn the valve. Be sure to use the correct size pipe wrench for the valve, and be careful not to damage the valve body or any nearby components.

It's important to note that a seized gate valve can be a sign of a larger plumbing problem, such as corrosion or debris buildup in the pipes. If you are unable to free the valve using these methods, or if you suspect a larger problem, it's a good idea to seek the assistance of a professional plumber, duplex stainless steel ball valve.

How to Open a Broken Gate Valve?

Opening a broken gate valve can be a difficult and potentially dangerous task. If the valve is broken, it's important to take appropriate safety precautions and seek the assistance of a professional plumber if necessary. Here are some general steps to open a broken gate valve:

Shut off the water supply: Before attempting to open a broken gate valve, you must first turn off the water supply to the valve. This can be done by locating the main water supply valve and turning it off.

Assess the damage: Once the water supply is shut off, you can assess the damage to the valve. If the valve handle is broken, you may be able to use pliers or a wrench to turn the stem of the valve. If the stem or gate is broken, you may need to replace the entire valve.

Apply penetrating oil: If the stem is stuck or difficult to turn, you can try applying a penetrating oil to the stem. This can help to break up any corrosion or debris that may be causing the stem to stick.

Use a pipe wrench: If the stem is still difficult to turn, you can try using a pipe wrench to turn the stem. Be sure to use the correct size pipe wrench for the stem, and be careful not to damage the stem or any nearby components.

Seek professional assistance: If the valve is still unable to be opened, or if you are unsure about how to proceed, it's a good idea to seek the assistance of a professional plumber. They will be able to assess the damage and determine the best course of action for repairing or replacing the valve.

It's important to note that opening a broken gate valve can be dangerous, as it may cause water damage or flooding. If you are unsure about how to proceed, or if you are unable to shut off the water supply, it's a good idea to seek the assistance of a professional plumber.

How to Identify Gate and Globe Valve?

Gate and globe valves are both types of valves commonly used in piping systems. Here's how you can identify them:

Gate valve: A gate valve has a flat or slightly curved disc that moves up and down to control the flow of fluid through the valve. The disc is typically perpendicular to the flow of fluid when fully open, creating a straight-through passage for the fluid. Gate valves are usually larger in size and used in applications where a full flow or shutoff is required, fugitive emission gate valve.

Globe valve: A globe valve has a disc that moves up and down and a stationary ring-shaped seat. The disc moves perpendicular to the flow of fluid and is typically angled, which allows for greater control over the flow rate of the fluid. Globe valves are usually smaller in size and used in applications where a precise flow control is required.

To visually identify the two types of valves, look at the shape of the valve body and the position of the stem. A gate valve will typically have a rectangular or circular body with a stem that moves up and down to open and close the valve. A globe valve will have a more rounded body with a stem that moves in a circular motion to control the flow of fluid.

Another way to identify the two valves is to look for their application. Gate valves are commonly used in applications where a full flow or shutoff is required, such as in pipelines, tanks, or boilers. Globe valves are commonly used in applications where precise flow control is required, such as in steam, water, or gas systems.

Contact Our Experts

Send us a message if you have any questions or request a quote.

We Offer:

A reply from our experts within 24 hours

The latest detailed product catalugue

One-stop service for your project

Company Details

Related Products

×

Contact Us To Download File

Get in Touch

×