1.Specification
Size: 2"-56"
Pressure: 150LB-2500LB
Body Material: WCB, WC6, WC9, CF8, CF8M, CF3, CF3M, CN7M, LC1, LC2, LC3, LCB, LCC, Monel, 20# Alloys, 4A, 5A, C95800, C95500, A105, F304, F304L, F316, F316L, LF1, LF2, LF3, LF9, F51, F53, F11, F22, etc.
Seal Material: PEEK, RPTFE, PTFE, DEVLON, HNBR, NYLON, AFLAS, STELLITE,etc.
Connection Type: Flanged, Butt Welded, Socket Welded, NPT
Operation: Hand lever, gear operated, pneumatic, motorized
Face to Face Dimension: ASME B16.10
Flange End Dimension: ASME B16.5
Butt Welded Dimension: ASME B16.25
Design and Manufacture: API 6D
Test Standard: API 598, API 607, API 6FA, ISO 15848-1-2
2.Features

Disassembly on the pipeline is simple and rapid, and maintenance is convenient and fast.

The ball is installed into the valve from the top part.

Prevent misoperation. The switch is equipped with locking device to prevent misoperation and ensure that the valve is in the correct position.

Top Entry ball valve is divided into floating ball valve and trunnion mounted ball valve.

The middle flange adopts tensile and compressive metal gaskets to enhance temperature resistance and prolong the service life effectively.

Operation device: lever, gear, pneumatic actuator, electric actuator, etc.

3.FAQ
Do Ball Valves Leak When Not Turned Completely?

Ball valves are designed to create a tight seal when they are fully closed, which prevents the flow of fluid through the valve. If a ball valve is not turned completely closed, there is a risk that it may leak, although the severity of the leak will depend on how far the valve is from being fully closed, ball valve manufacture.

A ball valve typically has a handle that rotates a ball inside the valve body. When the valve is fully closed, the ball is pressed tightly against the valve seat, which creates a seal that prevents fluid from flowing through the valve. If the valve is not turned fully closed, the ball may not be pressed tightly against the valve seat, which can allow fluid to leak through the valve.

The amount of leakage will depend on how far the valve is from being fully closed. If the valve is only slightly open, there may be only a small amount of leakage, which may not be noticeable. However, if the valve is significantly open, there may be a large amount of leakage, which could cause damage or create a safety hazard.

In summary, ball valves may leak when they are not turned completely closed. It is important to make sure that ball valves are fully closed to prevent leakage and ensure proper operation, gate valve manufacture.

How To Calculate Ball Valve CV?

The Cv (flow coefficient) of a ball valve can be calculated using the following formula:

Cv = Q / (sqrt(delta P) * SG)

Where:
Q = Flow rate in gallons per minute (GPM)
delta P = Pressure drop across the valve in pounds per square inch (PSI)
SG = Specific gravity of the fluid

To calculate the Cv, you will need to know the flow rate, pressure drop, and specific gravity of the fluid that will be flowing through the valve. Once you have these values, simply plug them into the formula and calculate the Cv, bronze valve.

It's important to note that the Cv calculation is based on water at 60°F as the reference fluid. If the fluid being used is different, a correction factor may need to be applied to the calculated Cv to account for the difference in viscosity and density.

How To Insulate a Ball Valve?

Insulating a ball valve is a fairly simple process that involves wrapping the valve with insulating material to reduce heat loss and prevent freezing. Here are the steps to insulate a ball valve:

Turn off the flow of liquid through the valve and allow the valve to cool down if it was recently in use, api 6d ball valve.

Clean the exterior of the valve with a cloth to remove any dirt, debris or moisture.

Choose the appropriate insulation material for the valve. There are various options available, including foam, fiberglass, and rubber.

Cut the insulation material to the appropriate length and width to fit around the valve.

Wrap the insulation material around the valve, making sure to cover the valve body and any exposed pipes connected to the valve.

Use adhesive tape to secure the insulation material in place. Be sure to overlap the edges of the insulation to ensure complete coverage.

Check the insulation periodically to ensure it is still securely in place and has not become damaged or worn, forged ball valve.

By insulating your ball valve, you can save energy and prevent freezing, which can ultimately help reduce maintenance costs and prolong the life of the valve.

What is Top Entry Ball Valve?

A top entry ball valve is a type of valve that features a top entry design, meaning that the valve body can be opened from the top to allow for easy access to the internal components for maintenance or repair.

The valve itself is a ball valve, which means it has a ball-shaped disc inside that rotates to control the flow of fluid through the valve. Top entry ball valves are commonly used in industries such as oil and gas, chemical, and petrochemical where there is a need for frequent maintenance or inspection, carbon steel gate valves.

This design offers several advantages over traditional side entry ball valves, including reduced downtime and maintenance costs since the valve can be serviced without needing to remove it from the pipeline. Additionally, top entry ball valves are typically more robust and can handle higher pressures and temperatures than their side entry counterparts.

When to use Stainless Steel Ball Valves?

Stainless steel ball valves are commonly used in applications that require reliable and long-lasting flow control. They are known for their durability, resistance to corrosion and rust, and their ability to withstand high pressure and temperature.

Stainless steel ball valves are typically used in industries such as oil and gas, chemical processing, pharmaceuticals, food and beverage, and water treatment. They are also used in applications where hygiene is critical, such as in the medical and biotech industries.

Here are some specific situations where stainless steel ball valves may be particularly appropriate:

High-pressure and high-temperature applications: Stainless steel ball valves are capable of withstanding extreme conditions, making them an ideal choice for high-pressure and high-temperature applications.

Corrosive environments: Stainless steel is highly resistant to corrosion and rust, making it an ideal material for ball valves in environments that are prone to corrosion, such as chemical processing plants and offshore oil rigs.

Hygienic applications: Stainless steel ball valves are easy to clean and sterilize, making them a good choice for applications that require high levels of cleanliness and hygiene, such as in the food and beverage industry or in medical and biotech applications, high temperature gate valves.

Long-term use: Stainless steel ball valves are known for their durability and longevity, making them a good choice for applications where long-term use is expected.

Overall, stainless steel ball valves are a reliable and versatile choice for a wide range of industrial and commercial applications.

Contact Our Experts

Send us a message if you have any questions or request a quote.

We Offer:

A reply from our experts within 24 hours

The latest detailed product catalugue

One-stop service for your project

Company Details

Related Products

×

Contact Us To Download File

Get in Touch

×