Forged Steel Swing Check Valve

Forged Steel Swing Check Valve

1、You are in restricted area and need password. Please Contact us to obtain documents.

2、PasswordIf you have any questions about quotation or cooperation, please feel free to send us inquiry. Inquiry us

Brochure:
Manual: Download
3D step: Download
Certificates: Download
Quote
1.Specification
Size: 1/2"-2"
Pressure: 150LB-2500LB
Body Material: A105, F304, F304L, F316, F316L, LF1, LF2, LF3, LF9, F51, F53, F11, F22, etc.
Seal Material: STELLITE, 13Cr, SS304, SS316, etc.
Connection Type: Butt welded
Face to Face Dimension: ASME B16.10
Flange End Dimension: ASME B16.5
Butt Welded Dimension: ASME B16.25
Design and Manufacture: API 602
Test Standard: API 598,API 6FA, ISO 15848-1-2
2.Features

Usually suitable for sizes of 2 inches and below

Available with full bore and reduced bore

Small size, simple but compact structure

Bolted bonnet & welded bonnet & pressure seal bonnet & union bonnet

Flange type & butt welding type & socket welding type & NPT type & wafer type & lug type

Carbon steels such as A105, LF2, F11 and F22 are usually treated with phosphating.

Suitable for petroleum, chemical, pharmaceutical, chemical fertilizer, power industry, low temperature, and other conditions of the pipeline

3.FAQ
Can you install a swing check valve vertically

Yes, a swing check valve can be installed vertically. The swing check valve is designed to allow flow in one direction and prevent backflow. It consists of a disc that swings on a hinge or pivot. When the flow is in the desired direction, the disc swings open, allowing the fluid to pass through. When the flow reverses, the disc swings closed, preventing backflow. This type of valve can be installed in both horizontal and vertical orientations, as long as the flow direction is properly aligned with the valve. api 6d ball valve

What are swing check valves used for

Swing check valves are a type of check valve that uses a swinging disc to control the flow of fluid. The disc swings open to allow fluid to flow in one direction and swings closed to prevent backflow in the opposite direction. Swing check valves are commonly used in applications where there is a need to prevent backflow and protect equipment from damage.

Some common applications of swing check valves include:

1. Water supply systems: Swing check valves are commonly used in water supply systems to prevent backflow of contaminated water into the clean water supply.

2. Sewage systems: Swing check valves are used in sewage systems to prevent backflow of sewage into the clean water supply. forged ball valve

3. Oil and gas pipelines: Swing check valves are used in oil and gas pipelines to prevent backflow of fluids that could damage equipment or cause safety hazards.

4. HVAC systems: Swing check valves are used in heating, ventilation, and air conditioning (HVAC) systems to prevent backflow of air or fluids that could damage equipment or cause safety hazards.

Overall, swing check valves are an important component in many piping systems to prevent backflow and protect equipment from damage. carbon steel gate valves

How to test a swing check valve

To test a swing check valve, you can follow these steps:

1. Close the valve: Ensure that the swing check valve is in the closed position by turning off the flow of fluid to the valve.

2. Inspect the valve: Visually inspect the valve for any signs of damage or wear, such as cracks, corrosion, or leaks. If any issues are found, the valve should be repaired or replaced before testing.

3. Apply pressure: Apply pressure to the valve by turning on the flow of fluid to the valve. The pressure should be gradually increased to the maximum operating pressure of the valve.

4. Observe the valve: Observe the valve to ensure that it opens and closes properly. The swing check valve should open when the fluid flows in the desired direction and close when there is a reversal in the flow direction or a decrease in pressure.

5. Check for leaks: Check for any leaks around the valve body or the sealing surfaces. If any leaks are found, the valve should be repaired or replaced. high temperature gate valves

6. Repeat the test: Repeat the test several times to ensure that the valve operates consistently and reliably.

Overall, testing a swing check valve involves inspecting the valve, applying pressure, observing the valve's operation, checking for leaks, and repeating the test several times to ensure consistent performance.

What is a dual plate check valve

A dual plate check valve, also known as a double disc check valve, is a type of check valve that consists of two half-discs or plates that are hinged together in the center. These plates are designed to swing open and allow the flow of fluid in one direction, and then swing closed to prevent backflow in the opposite direction, low temperature ball valves.

The dual plate design offers several advantages over other types of check valves. Firstly, it provides a compact and lightweight solution, making it suitable for applications where space is limited. Secondly, the dual plate configuration allows for a quick and efficient response to changes in flow direction, reducing the risk of water hammer and pressure surges. Additionally, the design of the plates minimizes the pressure drop across the valve, ensuring efficient flow and reducing energy consumption.

Dual plate check valves are commonly used in various industries, including oil and gas, water and wastewater treatment, chemical processing, and power generation. They are suitable for both horizontal and vertical installations and can handle a wide range of fluids, including liquids, gases, and slurries, api602 forged gate valve.

In summary, a dual plate check valve is a type of check valve that consists of two hinged plates that swing open to allow flow in one direction and swing closed to prevent backflow. It offers compactness, quick response, low pressure drop, and versatility, making it a popular choice in various industries.

Why is my check valve leaking

There are several reasons why a check valve may be leaking. Here are some possible causes:

1. Worn or damaged seal: The seal in the check valve may become worn or damaged over time, causing it to leak. This can happen due to normal wear and tear or exposure to harsh chemicals or high temperatures.

2. Improper installation: If the check valve is not installed correctly, it may not function properly and could leak. For example, if the valve is not aligned properly or if the connections are not tightened enough, it could cause leaks.

3. Debris or buildup: Debris or buildup in the valve can prevent it from closing properly, causing leaks. This can happen if the valve is not cleaned regularly or if there is a buildup of sediment or other materials in the pipeline.

4. High pressure: If the pressure in the pipeline is too high, it can cause the check valve to leak. This can happen if the valve is not designed to handle the pressure or if there is a sudden surge in pressure.

5. Corrosion: Corrosion can cause the valve to deteriorate over time, leading to leaks. This can happen if the valve is made of a material that is not resistant to corrosion or if it is exposed to corrosive substances.

If your check valve is leaking, it is important to identify the cause of the problem and take appropriate action to fix it. This may involve replacing the valve, cleaning it, or adjusting the installation.

Contact Our Experts

Send us a message if you have any questions or request a quote.

We Offer:

A reply from our experts within 24 hours

The latest detailed product catalugue

One-stop service for your project

Company Details