1.Specification
Size: 2"-36"
Pressure: 150LB-2500LB
Body Material: WCB, WC6, WC9, CF8, CF8M, CF3, CF3M, CN7M, LC1, LC2, LC3, LCB, LCC, Monel, 20# Alloys, 4A, 5A, C95800, C95500, A105, F304, F304L, F316, F316L, LF1, LF2, LF3, LF9, F51, F53, F11, F22, etc.
Seal Material: STELLITE, 13Cr, SS304, SS316, etc.
Connection Type: Wafer
Face to Face Dimension: ASME B16.10
Flange End Dimension: ASME B16.5
Design and Manufacture: API 594
Test Standard: API 598,API 6FA, ISO 15848-1-2
2.Features

Available with single plate disc and dual plate disc

Applicable with wafer ends, lug ends, double flange ends

Retainerless design, spring return, and integral seat are available.

Design standard according to API594, pressure test standard according to API598

Small volume, simple structure, long life service

3.FAQ
Is a foot valve a check valve

Yes, a foot valve is a type of check valve. More specifically, it is a specialized type of check valve that is designed for specific applications, typically in suction or lift applications in fluid systems, such as water wells, irrigation systems, and certain industrial processes. The primary purpose of a foot valve is to prevent the reverse flow of fluid (liquid) when the system is not actively in operation. api 6d ball valve

Here are some key characteristics of a foot valve as a type of check valve:

1. **Position:** A foot valve is typically installed at the end of a suction line in a well, pump, or other fluid handling system. It is positioned at the bottom of the suction pipe or hose and submerged in the fluid being pumped.

2. **Design:** Foot valves have a valve body with an opening at the bottom (the foot) and a check mechanism inside. The check mechanism allows fluid to flow into the system but prevents backflow when the pump is not running. forged ball valve

3. **Use in Suction Applications:** Foot valves are commonly used in applications where the pump operates by creating a partial vacuum to lift or suction fluid from a lower source. They help maintain prime in the pump and suction line by preventing the water from flowing back down when the pump is turned off.

4. **Strainer or Screen:** Many foot valves also include a built-in strainer or screen at the bottom to prevent debris or particles from entering the pump or system. The strainer helps ensure that the fluid being drawn into the system is clean and free of contaminants.

5. **Manual Priming:** Foot valves often require manual priming during initial installation to fill the pump and suction line with fluid. Once the pump is primed and operational, the foot valve maintains prime by preventing backflow. carbon steel gate valves

6. **Materials and Durability:** Foot valves are typically constructed from materials suitable for the type of fluid being handled and designed to withstand submersion and exposure to water or other fluids.

In summary, a foot valve is a type of check valve specifically designed for applications involving suction or lift, such as in well pumps and irrigation systems. Its function is to prevent backflow and maintain the prime in the system, ensuring that the pump operates efficiently. It incorporates typical check valve principles but is adapted for its specific application. high temperature gate valves

What is a dual check valve

A "dual check valve" is not a standard term in the context of valves or fluid control devices. However, it's possible that you are referring to a "double check valve" or a "dual check backflow preventer."

A double check valve assembly (DCVA) is a type of backflow prevention device used to protect water supplies from contamination or pollution due to backflow. It consists of two independent, spring-loaded check valves installed in series, with test ports for each check valve. A DCVA is commonly used in plumbing systems and water supply networks to provide a reliable barrier against backflow, low temperature ball valves.

The dual check backflow preventer you might be referring to is essentially a double check valve assembly. Here's how it works:

Two Check Valves: A dual check valve assembly comprises two check valves installed in a single housing, one after the other. Each check valve operates independently.

Normal Flow (Open Position): During normal flow, water or fluid moves through the assembly in the forward direction. Both check valves open, allowing the flow to pass through.

Backflow (Closed Position): If there is a drop in pressure or a reversal of flow, the check valves close to prevent the reverse flow or backflow. The dual check valve assembly functions as a backflow preventer by having two barriers to ensure backflow is effectively blocked.

These assemblies are designed to provide a higher level of protection against backflow compared to a single check valve. They are used in various applications, such as in potable water systems, irrigation systems, and industrial processes, where the risk of backflow contamination must be minimized.

Dual check valve assemblies are typically subject to periodic testing and maintenance to ensure they are functioning correctly and providing adequate backflow protection. Local plumbing codes and regulations often dictate the installation, testing, and maintenance requirements for these devices.

What is a silent check valve

A silent check valve, also known as a silent or quiet check valve, is a type of check valve designed to reduce or eliminate the typical water hammer noise associated with the sudden closure of a check valve. Water hammer is a hydraulic shock or pressure surge that occurs when a fluid flow is suddenly stopped or redirected, causing a shockwave in the piping system. This phenomenon can be noisy and potentially damaging to pipes and equipment. Silent check valves are specifically engineered to address this issue.

Here are the key characteristics of a silent check valve:

1. **Noise Reduction:** Silent check valves are designed to minimize or eliminate the "slamming" noise that occurs when traditional check valves close quickly due to backflow. This noise can be disruptive and damaging, particularly in water supply systems.

2. **Slow Closure Mechanism:** Silent check valves feature a mechanism that controls the closing speed, allowing the valve to close slowly and gradually. This reduces the shockwave and noise associated with the sudden cessation of flow.

3. **Internal Damping:** Some silent check valves incorporate internal damping components, such as dashpots or spring-loaded mechanisms, to further reduce the impact of closing and minimize noise, api602 forged gate valve.

4. **Spring-Assisted:** Many silent check valves are spring-assisted, meaning that they use a spring to assist in closing the valve. This ensures a controlled and gradual closing motion.

5. **Applications:** Silent check valves are commonly used in plumbing and water supply systems where noise reduction is essential, especially in residential, commercial, and industrial settings.

6. **Compatibility:** Silent check valves are available in various materials and designs to suit different applications and fluid types, including water, wastewater, and various liquids.

While silent check valves are effective at reducing water hammer noise and protecting piping systems, they may have a slightly higher initial cost than traditional check valves. However, their benefits in terms of noise reduction and potentially extended equipment life can make them a valuable choice in many applications. These valves are also typically installed in horizontal piping systems, and it's crucial to ensure that they are properly sized and installed for optimal performance.

What is butterfly type check valves

Butterfly type check valves are a type of check valve that uses a disc-shaped closure member, similar to a butterfly valve, to regulate the flow of fluid. The disc is mounted on a hinge or shaft and swings open in the direction of flow when the pressure on the upstream side exceeds the pressure on the downstream side. When the flow reverses, the disc swings closed and prevents backflow. Butterfly type check valves are commonly used in applications where low pressure drop and quick response are required, such as in HVAC systems, water treatment plants, and fire protection systems.

What is the applicable temperature for butterfly type check valves

The applicable temperature for butterfly type check valves depends on the materials used in their construction. Generally, butterfly type check valves can handle a wide range of temperatures, from -29°C (-20°F) to 427°C (800°F) or even higher, depending on the specific design and materials. However, it is important to note that the temperature limits may vary based on factors such as the type of sealing material, the type of disc material, and the overall construction of the valve. It is recommended to consult the manufacturer's specifications or guidelines to determine the specific temperature range for a particular butterfly type check valve.

Contact Our Experts

Send us a message if you have any questions or request a quote.

We Offer:

A reply from our experts within 24 hours

The latest detailed product catalugue

One-stop service for your project

Company Details

Related Products

×

Contact Us To Download File

Get in Touch

×